Specifications
Electrical parameters
Light source | LED |
Power voltage | AC 220–240 V / 50–60 Hz |
Connection method | leading out cable, leading out cable with connector (G), without cable (WO) |
Ballast part | electronic driver with surge protection L/N-Ground 10 kV |
Surge protection | additional surge protection 10 kV (S) |
Fuse | fuse 6,3 A (J) |
Possibility of regulation | non-dimmable (not labeled), DALI (DALI), night dimming (A) preparation for wireless communication NEMA (N), Zhaga (Z) or 2× Zhaga (Z2) |
Constant lumen output | CLO (C) |
Light parameters
Optical system | roads (Mxx), roads (Lxx), directional (Pxx) area (Uxx), combined optics (Kxx) |
Light distribution | direct |
Colour rendering index | Ra > 70, Ra > 80 |
Colour temperature | 2,700 K / 3,000 K / 4,000 K / 5,000 K |
Service life | > 100,000 hrs. (L90B10) |
Construction
Luminaire body | aluminum cast |
Colour | RAL 7015/9006, other RAL (on request) |
Surface type | matte |
Luminaire cover | tempered glass |
Safety
Protection class | I, II |
Maximum ambient temperature | -40 / 50 °C |
Protection of the luminaire's electrical part | IP 66 |
Protection of the luminaire's optical part | IP 66 |
Mechanical durability | IK 09 (EN 62262:2002) |
Certification | ENEC, Zhaga-D4i, IDA Dark Sky Approved |
CB mark | YES |
Mounting
Method | pole or boom mounted (48–60 mm); 60–76 mm (on request) adjustable joint ± 20° |
Recommended height | max. up to 15 m |
Use | outdoor areas, road classes I. and II. |
Variants
* Can not be produced under ENEC licence
** Weight may vary depending on the luminaire variant
Luminaire ambient temperature TQ 25 °C
Initial color consistency: ≤ 5 SDCM
IDA fixture seal of approval relates to ≤ 3 000 K
To meet IDA requirements, the luminaires must be installed horizontally with the road
Optical and electrical parameters tolerance ± 10 %
When using the CLO function, the initial power and luminous fluxis 10 % lower than the value shown in the table.
LDT curves with CLO function have the letter “C” at the end of their marking.